AC & DC Current Monitoring

AC & DC current monitoring

AC & DC Current Monitor

System Description

Vutlan AC & DC Current Monitoring Solutions provide comprehensive tools for monitoring and managing power consumption in AC and DC circuits within data centers, telecommunications, and industrial environments. These solutions enable administrators to track energy usage, optimize power distribution, and ensure that critical systems run within safe electrical parameters. With real-time monitoring and alerting, Vutlan’s current monitoring devices help safeguard equipment, improve operational efficiency, and minimize potential downtime.


Used for

Vutlan AC & DC Current Monitoring Solutions are designed to provide advanced monitoring and management for electrical current in AC and DC circuits, making them highly versatile tools for various industries. Below are some of the primary use cases for Vutlan’s current monitoring systems:

1. Data Centers

  • Power Load Management: In data centers, current monitoring is crucial for managing power loads across servers and racks. Vutlan’s current monitoring solutions enable IT managers to track power consumption, balance loads, and prevent overloading, ensuring consistent performance.
  • Energy Efficiency Optimization: With real-time monitoring and detailed energy usage reports, data centers can identify areas of excessive consumption and adjust power allocation. This helps reduce operational costs and improves overall energy efficiency.

2. Telecommunications Facilities

  • Stable Power for Critical Equipment: Telecommunications equipment relies on stable power, especially in remote or unmanned facilities. Vutlan’s current monitoring solutions allow remote monitoring of power status and current usage, helping to prevent outages and maintain continuous service.
  • Environmental and Power Monitoring: Many telecom setups require monitoring of both environmental and electrical parameters. Vutlan’s solutions can be paired with temperature, humidity, and other sensors to provide a complete monitoring system, protecting equipment from overheating and electrical faults.

3. Industrial Automation and Manufacturing

  • Preventive Maintenance: In industrial settings, machinery and automation systems often have high power demands. Monitoring the current and power usage with Vutlan’s devices can help detect unusual patterns or spikes in consumption, which may indicate the need for maintenance before a breakdown occurs.
  • Protection of Sensitive Equipment: Heavy industrial equipment is sensitive to fluctuations in current and voltage. Vutlan’s solutions help ensure that equipment operates within safe parameters, reducing the risk of electrical damage, downtime, and costly repairs.

4. Renewable Energy Systems

  • Monitoring DC Power: Many renewable energy sources, such as solar panels and wind turbines, generate DC power. Vutlan’s DC current monitoring capabilities allow for tracking and managing power production and storage, ensuring efficient distribution within the system.
  • Battery and Storage Monitoring: In renewable energy installations, storage systems like batteries require monitoring to maintain performance and longevity. Vutlan devices can monitor current flow to and from batteries, helping optimize charging cycles and prevent overcharging or deep discharging.

5. Building Management Systems (BMS)

  • Energy Usage Tracking: In commercial buildings, current monitoring helps facility managers track and optimize energy use across lighting, HVAC, and other systems. Vutlan’s monitoring devices provide valuable insights for reducing energy costs and improving sustainability.
  • Alerts for Electrical Issues: Vutlan’s current monitoring systems can detect anomalies and send alerts when current exceeds safe levels. This helps facility managers quickly address electrical issues that could impact building operations and tenant safety.

6. Remote and Unmanned Facilities

  • Remote Power Monitoring: Many industries operate unmanned facilities, such as telecom towers, offshore rigs, and substations, where reliable power monitoring is essential. Vutlan’s solutions allow for remote monitoring and management, giving administrators insight into power status and environmental conditions from any location.
  • Alerting and Automated Responses: For facilities that are not always staffed, Vutlan’s solutions can send alerts and trigger automated responses when current, voltage, or environmental conditions exceed predefined thresholds, ensuring prompt intervention without requiring on-site personnel.

7. Research and Testing Laboratories

  • Precise Power Monitoring for Equipment: Research facilities and testing labs often require consistent power to operate sensitive and expensive equipment. Vutlan current monitoring helps protect lab equipment from voltage fluctuations and monitor energy consumption.
  • Data Collection for Analysis: Vutlan’s monitoring solutions can provide detailed data on power usage and current draw, which is valuable for researchers who need precise measurements to analyze equipment performance and optimize setups.

Summary of Benefits Across Use Cases

  • Enhanced Equipment Protection: By ensuring equipment runs within safe current and voltage limits, Vutlan’s monitoring solutions reduce wear and extend equipment lifespan.
  • Operational Efficiency: Real-time data allows for informed decision-making, enabling managers to improve power distribution and reduce unnecessary energy consumption.
  • Cost Savings: Identifying power usage trends and optimizing loads can lead to significant reductions in energy costs.
  • Improved Safety: Alerts for overcurrent or voltage anomalies help prevent electrical hazards, protecting both personnel and equipment.

Vutlan AC & DC current monitoring solutions are indispensable tools across various industries, providing both operational insights and enhanced control to improve safety, efficiency, and sustainability.


AC Current Monitoring

100A transducer is used for the measurement of AC current. The system interface allows you to assign a transducer and to introduce the function data conversion. VT407 / HAT transceiver can be used together with HAT-100Q1 to convert data into the format of Vutlan monitoring system. The transducer consists of a plastic housing with an open/closed AC current loop and 4 pins terminal connector. The current transceiver is a simple plastic case with 4 pins input, power 12V socket, and analog 0-5V RJ12 output.

Example: Measuring current in AC power circuit

Sensor for measuring current in 230V and 110V installations using Vutlan open-loop contactless hall sensor and a converter enables you to create an early warning system against overloading the electricity supply or individual lines.

ACC Power Circuit
Prediction of equipment

Example: Life prediction of equipment

As the electric elements age in the equipment, its resistance also changes. By measuring the current drawn by the element using Vutlan current transducer the resistance of the element can be determined and compared against a known aging characteristic. When the element reaches a predetermined state it can be replaced prior to failure.

Example: Turn off equipment before it overloads

As the electric elements age in the equipment, its resistance also changes. By measuring the current drawn by the element using Vutlan current transducer the resistance of the element can be determined and compared against a known aging characteristic. When the element reaches a predetermined state it can be replaced prior to failure.

Overload
Control Center

Notify personnel and control center of equipment jam

In case of low current, notify personnel by switching on the alarm beacon and notifying the control center using an E-mail, SMS, Syslog, Event log, SNMP Trap, or SNMP Get.

DC Current Monitoring

The transducer is used together with the HOS-100Q1 DC Hall current transducer for sensing current and converting data into the format of the IP monitoring system. HOS-100Q1 can sense in which direction the current is flowing, this is an ideal solution for monitoring UPS and Battery charging and life prediction. The system interface allows you to assign the current meter and to introduce the function data conversion. The transducer consists of a plastic housing with an open/closed AC current loop and 4 pins terminal connector. The current transceiver is a simple plastic case with 4 pins input, power 12V socket, and analog 0-5V RJ12 output.

DC Current Monitor
Battery Charging or UPS

Example: Monitor battery charging or UPS

If the hall sensor is installed in such a way that its arrow, drawn on it, points towards the battery, then: If the battery is charging, the sensor shows that the current is ”+”; If the battery is discharging, the sensor shows that the current is ”-”.