Our web interface is flexible enough to empower you with all the tools you need to monitor and control your mission-critical facility. It is embedded in each remote monitoring unit and can be accessed with an IP address inside your browser.


Simplicity & Flexibility

Simplicity & Flexibility

The interface is built-in inside every Vutlan monitoring unit. Simply type in the IP address of the unit in the browser. Real-time dashboards with live updates and status information. The menu is divided into sections: Overall Stats, System Tree, Dry Contacts, Event Log, Logic Schemes, Cameras, Map, Users, CAN configuration, Graphs, Outlets, Preferences, System Menu.

User Access and Permissions

User Access and Permissions

Using “view” and “write” rights, user access can be restricted to the subsystems of the device using groups of access permission. User access can also be restricted to a specific group of sensors, which is defined by the administrator. This allows defining users for view or control of specified subsystems, allowing clients or employees to be in charge of monitoring their own equipment or part of a facility.

Advanced Notifications

Advanced Notifications & Alerts

7 notification technologies: Send Email, SMS, Syslog, Event log, SNMP Trap, SNMP Get, sound, and light an alarm beacon or a strobe light. Alerts based on thresholds (warning, alert, normal). Multiple condition alerts. Escalation alerts (extra notifications every x min during downtime). Dependencies (avoid alarm floods). Alert Scheduling (based on time of the day).

Configurable Logic Schemes

Configurable Logic Schemes

Logic schemes are used to specify automatic actions to events that occur in the system. Logic schemes represent a set of conditions “IF” and a set of actions that are executed “THEN”. Conditions can be combined using “AND” and “OR”. For Example, you have a telecommunication rack with servers and equipment. You need to activate fans inside a rack when the temperature reaches 36°C. If the temperature reaches 44°C you need to activate the second fan and notify the administrator via e-mail and SMS.

Mobile interface

Mobile interface

Vutlan web Interface is optimized for mobile and tablet devices. It can be viewed and controlled from any mobile browser.

Sensor graphing

Sensor graphing

Detailed graphs and data tables for one or more sensors using the multi-plot graphs. Each graph shows data for the last 100: seconds, minutes, hours, days.

Multi Language Support

Multi Language Support

Our web interface is available in English, Russian, German, French, Italian, Spanish, Czech, Polish, and Korean.

If you require another language, it is easy to make a translation using the *.json translation file.

Web interface Panels

Web interface Panels
Dashboard panel

The system allows you to customize the dashboard individually for each user. And display the most important information about system elements, sensors, and devices in a visual form. The view of the dashboard element depends on the data it represents. Read more…

Overall stats panel

The panel shows current general statistics of the system and its elements such as several elements, their status, current log, time, and general system information. Read more…

System tree panel

The panel contains a categorized list of all elements connected to the system. Inside this panel, you can add new elements, edit configurations, view graphs for each element, and create groups of elements. Each element can be monitored, controlled, and configured for event authorizations.

Dry contact inputs panel

The “Dry inputs” panel shows all dry input terminals, and dry input extension devices connected to the system. You can configure normal and reverse states, rename elements, set defined types, create groups.

It is possible to add more dry contact inputs by using VT440 / Dry contact extension unit. Read more…

Event log

A list of the latest system events is available in the “Event log” menu. Read more…

Logic schemes

Logic schemes represent a set of conditions “IF” and a set of actions that are executed “THEN”.  Conditions can be combined using “AND” and “OR”. They represent the automated events & preconditioned events in the system. They allow to automate alert conditions and events. Read more…

Cameras

Vutlan units may connect USB or IP cameras. USB camera MJPEG stream can be recorded and sent as video notifications. IP cameras can only be monitored, not recorded. Read more…

Virtual Sensors & Elements

Group of elements

Groups of elements are made for the structural organization of the elements in the system. Group notifications can be used. Any element of the group can trigger an event. Read more…

E-mail notification

E-mail notifications can be used to send e-mails in case an event has been triggered, for example, a temperature rise. Read more…

SNMP Trap

When the Vutlan monitoring device detects an error or a change, the device will send a notification to one or more trap receivers onto a specified IP address. Traps are only sent using logic schemes or group notifications. For example, if a logic scheme is activated, the trap will be sent to a trap receiver. Read more…

SMS notification

When the Vutlan monitoring device detects an error or a change, the device will send a notification to one or more trap receivers onto a specified IP address. Traps are only sent using logic schemes or group notifications. For example, if a logic scheme is activated, the trap will be sent to a trap receiver. Read more…

Web SMS

You can send SMS messages through special SMS services via Ethernet. Vutlan monitoring unit sends a request to such a service, which in return sends an SMS to the recipients, depending on the API in the request. Read more…

SMS gate

If several Vutlan devices are used in the same network, and at least one of them has an LTE modem, you can send SMS from other Vutlan devices that are not equipped with a modem. Read more…

Dial task call

Dialing a phone/mobile number allows you to attract the attention of a person to events in the system. Read more…

HTTP request

Allows you to send an HTTP request to the specified server. The server response is not parsed and cannot be used. Communicate with a server, PSIM (Electronic circuit simulation software package), SCADA (Supervisory Control and Data Acquisition), or software program. Read more…

Timer / Schedule

The timer allows you to plan the events in the system.  A timer is like a schedule, that can be set to operate once, weekly, or monthly. When the timer is triggered it goes from the normal state into an alarm state. When the timer is turned off it goes back to a normal state. Read more…

Trigger

The trigger element is designed to generate events in the system when logic is triggered or manually. The trigger element has two modes: normal and inverted.

A feature of the trigger element is that this element may be included in the list of input conditions (IF), and the list of actions performed (THEN) logic circuits. Such a feature can be used to create a connection between two independent logics. Read more…

PING

Ping is a utility used to test the reachability of a host network. In the absence of connection ping registers from a normal state to a state of alarm. After you restore the connection – Ping registers back to a normal state. 

For example, find out if the server, IP camera, or any other IP device is working. Read more…

SNMP GET

Virtual sensor “SNMP Get” is used to read data from external equipment via SNMP PDU GET (v1, v2c, v3). The “SNMP Get” sensor can be analog or discrete type. The analog sensor interprets the value read by SNMP as a decimal number, extraneous characters (if they are in the data line) are discarded. The discrete sensor compares the read value with the given sample (called “Normal value”), and if the sample is contained in the data line, then the element takes the state “normal”, if the sample is not in the line, it takes the state “alarm”. Read more…

Modbus RTU

A virtual “Modbus RTU” sensor is used to read and write data from external equipment via Modbus RTU protocol (RS-485 line). Such equipment can be sensors, meters, or systems. Vutlan supports READ & WRITE functions. Read more…

Modbus TCP

A virtual “Modbus TCP” sensor is used to read and write data from external equipment via Modbus TCP/IP protocol.
Support the Wake-on-LAN standard that allows a remote device to be turned on or awakened by a network message. Read more…

Math sensor element

The virtual “Math” sensor allows you to calculate the value according to the data of arbitrary sensors. For example, the diesel volume of an uneven tank can be calculated using a formula, some static data, and a level sensor data. Read more…

IP camera

An element “IP camera” is designed to display an MJPEG stream of images from surveillance cameras. The IP camera stream can not be recorded for video notifications, only viewed. Read more…

Dew point

The dew point of a given body of air is the temperature to which it must be cooled to become saturated with water vapor. You can chose a temperature and humidity sensor data to calculate a dew point. Read more…

Software specifications

Web Interface

Full monitoring and control over IP

First-time wizard

Time synchronization

Day / night cycles

Manual season time setup

Multi language web interface

Floor map plan with layers and vectors

System & group trees

SNMP protocol

 SNMP v1, SNMP v2c, SNMP v3

Support Cloud hosting software

Support DCIM

Logs

 System event log

FTP Logs

Syslog export to XML, CSV

SD card logs

USB flash drive logs

RSS export

Sensor dump files

Sensor log to e-mail

Receive notifications

E-mail alerts

SNMP Trap alerts

SMS notifications

Dial phone task

Web-to-SMS

SMS gate

Automation of events using logic

Logic schemes (IF, THEN, OR, AND events)

No programming skills needed

One time or repeated events

Control equipment

Send notifications

Event triggers

Group events

Duplicator program

Duplicator license is purchased separately

For management of multiple devices

Upload configuration and firmware

User access

3-Tier user access

Guest, Operator, Admin

RADIUS centralised user database

Networking

OpenVPN client

OpenVPN server

Routing

DynDNSSSLHTTP, HTTPS, TLS, DHCP

Open API

Send notifications

SNMP GET element

HTTP request

Firmware upgrade

By HTTP

By USB

Factory restore

Cameras

USB camera (JPEG stream notifications)

IP cameras (only view)

Virtual sensors

PING

Timer / Schedule

Trigger

Modbus TCP

Math sensor

Dew point

Groups

Back up settings

Monitoring: modules, sensors, groups, map, USB web-cam & etc.
CAN bus configuration
Users DB
Access keys DB
Date and time configurations
Network settings
HTTP Server settings
Logging settings
Radius settings
SNMP settings
DynDNS
Settings of update
Settings of backup

Security & Network

No SSH

SSL cerrtificate

OpenVPN client & server

Routing

NTP server

Dynamic DNS

Radius server

Graphs

Sensor graphs

Multi sensor graphs